{"product_id":"blitz-x-uras-d1-spec-sbc-i-d","title":"Blitz x URAS D1 Spec SBC i-D Boost Controller","description":"\u003cp\u003e\u003cstrong\u003eThis is a USED item, we have tested it and confirmed operation\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan class=\"rQesXe MPyX\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis unique boost controller represents the cutting edge in boost controller technology. The SBC i-D features the same dual solenoid design as the DSBC for maximum boost response and the capability to hold up to 36.75psi (2.5 bar). The SBC i-D III is 1\/2 din size and it is compatible with internal actuators and external wastegates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eFeatures\u003cbr\u003e\u003cbr\u003eBoost Unit -\u003cspan\u003e Can display boost in PSI, bar, KPA, and kg\/cm2. Four Channels - Has four different programmable boost settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eBoost Gauge and Peak Hold -\u003cspan\u003e This boost controller has a built in boost gauge and peak hold that can be display in both graph and digital form.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eBoost Warning and Limiter\u003cspan\u003e - This is a safety function that allows the user to set the amount of boost decrease in the event of any over boost. Warning in visual display and audible warning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eScramble Boost\u003cspan\u003e - The scramble boost feature allows the user to set an increase or decrease in boost for a desired amount of time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eManual or Automatic Boost Setting -\u003cspan\u003e The SBC i-D allows the user to set boost both in manual and automatic.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAutomatic\u003cspan\u003e - Sets boost directly, just dial in desired boost setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eManual -\u003cspan\u003e Sets boost in ration, this setting will give maximum boost response. Recommended for high boost vehicles and large turbo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eDisplay\u003cspan\u003e - Can display up to 6 different readings, Each reading can be displayed in both digital and graphical form. SBC i-D has the option to display 5 different vehicle readings. Power Meter i-D and SBC Optional harness are needed to display other readings. With Power Meter i-D connected, the SBC i-D can display SPEED and POWER. With SBC Optional Harness connected, the SBC i-D can display different electronic output from the ECU (ie. TPS, water temperature, oil pressure, A\/F, injector pulse).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBOOST: Digital and Graphical\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOPT1 \/ SPEED (Power Meter i-D required to display speed): Digital and Graphic Display\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOPT2 \/ POWER (Power Meter i-D required to display power): Digital and Graphical Display\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDATA 1 (SBC Optional harness required): Digital and Graphical Display\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDATA 2 (SBC Optional harness required): Digital and Graphical Display\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDATA 3 (SBC Optional harness required): Digital and Graphical Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eRecord and Replay\u003cspan\u003e - SBC i-D has the ability to record and replay any information that was displayed on the SBC i-D. The SBC i-D can also replay information on the Power Meter and any of the optional data that is displayed. Replay can be fast forwarded and replayed in 2x and 5x.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eSpeed Map -\u003cspan\u003e The SBC i-D has the ability to control boost by speed (Power Meter i-D required). This function allows the user to fine tune the boost according to the speed of the vehicle. If Speed Map is set up by the different boost channels, the boost controller will switch channels automatically according to the speed of the vehicle. Speed is transfered from the Power Meter i-D by the infrared connection between the SBC i-D and Power Meter i-D.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eOptional Display -\u003cb\u003e \u003c\/b\u003e\u003cspan\u003eThe SBC i-D has the ability to display any electronic outputs from the ECU (SBC Optional Harness required Part #15053). It can read TPS, water temperature, oil pressure, injector pulse, A\/F, and etc. The SBC Optional Harness will allow the SBC i-D to display up to 3 different readings, DATA 1~3. Any addition readings can be recorded and replayed.\u003c\/span\u003e\u003c\/p\u003e","brand":"Blitz","offers":[{"title":"Default Title","offer_id":68831644418242,"sku":null,"price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/8235\/8210\/files\/IMG_2034.jpg?v=1793738880","url":"https:\/\/jetdavis.parts\/products\/blitz-x-uras-d1-spec-sbc-i-d","provider":"jetdavis.parts","version":"1.0","type":"link"}